Products
Connection accessories Probes Long probe set 4 m
Long probe set 4 m – 271126
Long probe set 4 m
Long probe set 4 m including carrying system
included:
– 1x 1 m carbon extension with foam handle
– 3x 1 m carbon extensions
– triangle probe
– connecting hose for carbon probes, 1 m
– carrying system for long probe set
Prices for customers after registration
1
Article affiliation:
GOLIATH Biogas B
Rugged, explosion proofed gas measurement instrument
with internal membrane pump and reachargeable
NiMH-battery
for the specific use in biogas, landfill and sewage gas.
Operating time > 8 to > 12 hours depending on application
(without backlight)
Measurement ranges:
– methane 0 – 100 Vol.% CH4
– carbon dioxide 0 – 100 Vol.% CO2
– oxygen 0 – 25 Vol.% O2 (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– hydrogen sulphide 0 – 1000 ppm H2S (optional)
– hydrogen sulphide 0 – 2000 ppm H2S (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1200 g
Explosion proofed instrument:
Sign: ll 2G Ex ib d llB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C < Ta < +40°C
OLLI
Gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device.
It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with 3 alkaline manganese primary cells.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional secondary
cell and/or optional pump.
Operating time > 20 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument, marking:
II 2G Ex ib db IIB T4 Gb
BVS 17 ATEX E 043 X
Temperature range: -20°C <= Ta <= +50°C
OLLI INMETRO
OLLI INMETRO gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device. It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with a Li-Ion rechargeable battery.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional pump.
Operating time > 50 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument
Applied Brazilian standards:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60079-11
Marking: Ex db ib IIB T4 Gb
Certificates: DNV 22.0010 X
Temperature range: -20°C <= Ta <= +50°C
OLLI with certified measuring function
Gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device. It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with a Li-Ion rechargeable battery.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional pump.
Operating time > 50 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument (active & passive)
Measuring function certified for methane (CH4), propane (C3H8), oxygen (O2), carbon
monoxide (CO), carbon dioxide (CO2), hydrogen sulfide (H2S) according to the following
standards:
EN 60079-29-1
EN 50104
EN 45544-1
EN 45544-3
Marking: II 2G Ex ib db IIB T4 Gb
(EU-)type examination certificates:
BVS 17 ATEX E 043 X
TÜV 21 ATEX 8596 X
TÜV 21 PTG 7001 X
968/FSP 1940.05/21
Temperature range: -20°C <= Ta <= +50°C
OLLI INMETRO with certified measuring function
OLLI gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device. It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with a Li-Ion rechargeable battery.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional pump.
Operating time > 50 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument (active & passive)
Measuring function certified for methane (CH4), propane (C3H8), oxygen (O2), carbon
monoxide (CO), carbon dioxide (CO2), hydrogen sulfide (H2S) according to the following
European standards:
EN 60079-29-1
EN 50104
EN 45544-1
EN 45544-3
Applied Brazilian standards:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60079-11
Marking: Ex db ib IIB T4 Gb
Certificates: DNV 22.0010 X
Temperature range: -20°C <= Ta <= +50°C
HUNTER gas leak detector
HUNTER – gas leak detector
High sensitive professional gas detection instrument
for pipeline inspection and leak detection.
Selected sensors with humidity compensation and high sensitivity for methane.
Integrated powerful pump, rechargeable NiMH battery pack and
Bluetooth module for online data transfer to tablet computer.
Operating time:
> 10 hours including Bluetooth-data transfer
> 11 hours without Bluetooth-data transfer
Measurement range: 0 – 22.000 ppm methane
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1100 g
Temperature range: -10°C to +50°C
GOLIATH Allround without Ethane analysis
methane/propane and toxic gases
Detect – Warn – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Confined space entry
– Building inspection
– Bar hole testing
– Purging gas purity
Measurement ranges:
– methane ppm, LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– propane ppm, LEL, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– pressure measurement 0 – 2.000 hPa (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH Allround with Ethane analysis
methane and toxic gases
Detect – Warn – Measure – Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Confined space entry
– Building inspection
– Bar hole testing
– Purging gas purity
– Ethane analysis
Measurement ranges:
– methane ppm, LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– pressure measurement 0 – 2.000 hPa (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN without Ethane analysis
GOLIATH RN without Ethane analysis
methane/propane and toxic gases
Detect – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Building inspection
– Bar hole testing
– Purging gas purity
Measurement ranges:
– methane ppm, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– propane ppm, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN with Ethane analysis
GOLIATH RN with Ethane analysis methane and toxic gases
Detect – Measure – Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing – Above ground inspection
– Building inspection – Bar hole testing
– Purging gas purity – Ethane analysis
Measurement ranges:
– methane ppm, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RB
GOLIATH RB
methane/propane and toxic gases
Warn – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Confined space entry – Bar hole testing
– Purging gas purity
Measurement ranges:
– methane LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 20 Vol.% CO2
– propane LEL, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH LOK
GOLIATH Localisation LOC
methane/propane and toxic gases
Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Purging gas purity – Bar hole testing
Measurement ranges:
– methane Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 20 Vol.% CO2
– propane Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
Dimensions: 200 x 100 x 87 mm
weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C