Test head HEINZ 2 1/2" ext. thread P max: 60 bar
Test head (stainless steel) with 4 plugs for pressure instrument,
manual pressure gauge, electric waterpump and water flowmeter
Option AGFW FW 602
Menu-guided pressure test procedures for carrying out pressure tests on district heating pipes
according to AGFW FW 602 (Germany):
- Differential pressure measurement method (air)
- Pressure measurement method (air)
- Simultaneous pressure measurement (air)
- Water pressure test
Option ZTV TKNetz 40
Menu-guided pressure test procedure for speed net pipes according to
ZTV TKNetz 40 (Company instructions, Telekom, Germany)
Option Wastewater EN 1610
Menu-guided test procedures for carrying out pressure tests on wastewater pipelines and
manholes in accordance with the regulations EN 1610 (Europe), DWA-A 139 (Germany) and
DWA-M 149-6 (Germany).
This option includes the following menu items in the device:
Wastewater Procedure Air : Carry out the tests with the test medium air in accordance with the
regulations mentioned. EDS2-P 1 bar pressure sensor required.
Wastewater Procedure water: Carry out the tests with the test medium water in accordance
with the regulations mentioned. EDS2 level probe and EDS2 dosing valve required.
The menu item "Wastewater Procedure Water" will only be completed in Q2/2023 and can be
installed via an update of the device without additional booking as soon as it is available.
smart memo
Electronic pressure test case for pressure tests
with connection possibility of up to 5 external pressure or temperature sensors.
- the test procedures are menu-guided and can be carried out with
simple Data entry dialog
- a freely programmable pressure test is included
- optional test sequences for gas and water tightness tests
e.g. according to DVGW, ÖVGW, EWE, Avacon, WEVG.
- a subsequent addition of test sequences is possible easily
- large, illuminated display, even in direct sunlight easy to read
- Data entry and signature via touch display and foil keys
- Stylus for the touch display included
- Data memory for hundreds of measurements, depending on
test sequence
- Communication via Bluetooth for update, data transmission, printer
- LTE / GPS module (optional)
- robust case (IP 67)
- Operating time approx. 200 hours, extension with power supply
possible from outside
Dimensions: 220 x 90 x 168 mm
Weight: approx. 1450 g