OLLI Multi-Gas Detector - 280060
Select the required device options for your device here.
Description of gas detector & gas warning device OLLI
Manhole inspection: clearance measurement with OLLI
In the field of gas and water supply and sewage disposal, workplace monitoring and controlling the atmosphere in confined and enclosed spaces is a fixed and important part of work procedures according to DGUV Regel 113-004.
Before work can begin, it has to be ensured that there is no lack of oxygen and that the shaft atmosphere is free from harmful substances. Furthermore, it must be determined whether an explosive atmosphere can be ruled out. Especially for structures in the area of sewage disposal, a clearance measurement is mandatory.
Do you need a gas detector to inspect manholes? Then we offer you our OLLI, an effective gas detector with pump for combustible gases, toxic gases (H2S, CO, CO2) and oxygen, a perfect device for leak detection and repair (LDAR).
According to the German Employer's Liability Insurance Association (Berufsgenossenschaft), these gas warning devices "[...] are an aid to hazard reduction by detecting the presence of [flammable and] toxic gases and emitting suitable acoustic and/or optical warnings." (Quote DGUV Information 213-056).
In one of our workshops, the participants are taught necessary technical knowledge to perform clearance measurement in accordance with DGUV Principle 313-002.
Tutorial
Atmospheric testing in manholes
In this tutorial, we demonstrate how to use our OLLI gas detector for atmospheric testing.
* This video is currently only available in German. Please use YouTube’s subtitles to watch it.
Features of gas detector & gas warning device OLLI
- Individual device configuration possible for various applications
- High-contrast LCD graphic display with backlight for an optimal display of all measured values
- Useful additional functions (e.g. automatic start-up in the last-used application mode, display of valuable additional information, etc.)
- Simple and easy handling through intuitive menu navigation
- Very long operating time
- Brand new and highly effective filter technology
- Wireless data transfer for quick and easy transmission of data
- Practical accessories for all applications
- Functions and menu options in accordance with DVGW Worksheet G 465-4
- View measurement reports at any time and send them directly by email with the Data Subscription for the OLLI
Measurement data management with OLLI
It wasn’t that long ago that printing on thermal paper on site was a revolution. As an environmentally conscious and forward-looking company, we want to do away with paper whilst at the same time making your day-to-day work easier.
With Esders Connect, measurement data is transmitted directly to the office via the app on your smartphone or tablet – quickly, paperlessly and in compliance with the GDPR. You can specify up to three email addresses to which the completed test reports can be sent. Recipients receive not only the measurement data but also the GPS data showing the exact location of the measurement. The system is clearly organised and can be accessed at any time from anywhere.
Esders Connect is browser-based, so no updates are required and you always have the latest version available.
Click here for further information on Esders Connect.
smart AutoCal
The OLLI gas detector can be ideally combined with the smart AutoCal automatic test station to make day-to-day work noticeably easier. As a helpful aid, the station carries out the calibrations, adjustments and bump tests required by DVGW G 465 fully automatically.
Once connected, the OLLI is immediately and uniquely identified by its serial number, whereupon the appropriate test sequence starts straight away. Thanks to intelligent functions such as ‘Auto Device Test’ or ‘Auto Bump Test’, the system decides entirely on its own which test gases are required and automatically tests the pump’s function at the same time. A digital test report is then generated and conveniently uploaded to Esders Connect via the integrated LTE communication. This reduces manual maintenance to a minimum, ensuring that the OLLI is always reliably ready for use after testing. Further information on convenient device testing can be found here: smart AutoCal.
Measurement of gas volume
When purging pipelines, our OLLI can be used, equipped with a pressure sensor, in combination with our Mobile Gas Flares to measure the gas volume in the pipe. This also records the amount of methane or propane flared. This is important in the context of the documentation requirement for network operators arising from the EU Regulation to reduce methane emissions. The requirements of the DVGW regulations G 465-2 and G 404 are also implemented. You can find more information in our blog post Documentation for quantity measurement according to EU Methane Regulation.
Technical data
| Display | illuminated LCD Graphics display with 128 x 64 Pixel + special icons |
|---|---|
| Power supply | Rechargeable Li-Ion |
| Operating time | at least 50 hours (diffusion version, w/o backlight) at least 35 hours (pump version, w/o backlight) |
| Measurement range (Availability dependent on operating modes) | 0-1000 ppm methane/propane, resolution 1, 5, 10, 50 ppm (adjustable) 0-100 % LEL methane/propane, resolution 0.01 % or 0.1 % LEL (adjustable) 0-100 Vol.-% methane/propane, resolution 0.1 or 0.5 Vol.% optional: 0-5 Vol.% CO2, resolution 0.01 Vol.% optional: 0-25 Vol.% O2, resolution 0.1 Vol.% optional: 0-300 ppm CO, resolution 1 ppm optional: 0-100 ppm H2S, resolution 0.1 ppm optional: 0-1 bar, resolution 0.1 mbar |
| Alarm | Acoustic, optical and vibration alarm signal |
| Operating temperature | -20 °C to +50 °C |
| Protection | IP67 |
| Certification | Passive explosion-protection ATEX: BVS 17 ATEX E 043 X IECEx: IECEx BVS 21.0085X INMETRO: DNV 22.0010 X |
| ATEX labelling | Article No.: 280060 | II 2G Ex ib db IIC T4 Gb |
| INMETRO labelling | Article No.: 280030 | Ex db ib IIB T4 Gb |
| IECEx labelling | Article No.: 280060 | Ex ib db IIC T4 Gb |
| Dimensions | approx. 80 x 170 x 43 mm (pump version) |
| Weight | approx. 350 g incl. battery (diffusion version) approx. 380 g incl. battery (pump version) |
| Pump flow | approx. 20 l/h |
| Connectivity | IR, wireless data transfer |
| Data storage | approx. 200 MB |