Products
Connection accessories Probes Carbon bell probe T-bone handle
Carbon bell probe T-bone handle – 232086
Carbon bell probe T-bone handle
Carbon bell probe T-bone handle
For surface measurement in a rough terrain.
Prices for customers after registration
1
Article affiliation:
HUNTER H2
Gas detection device for easily locating even the
smallest leaks in water and heating systems
– special, highly sensitive hydrogen sensor with a resolution of 0,1 ppm H2
– extremely fast reaction to the smallest traces of hydrogen
– second sensor for pinpoint localisation in probe holes
– integrated pump with high power for flow and for negative pressure
Operation time:
> 10 hours without lighting
Measuring ranges:
0 to 1000 ppm H2
0 to 5 Vol.% H2 in N2
dimensions: 200 x 100 x 87 mm
weight: approx. 1100 g
temperature range: -10°C to +50°C
GOLIATH Allround without Ethane analysis
methane/propane and toxic gases
Detect – Warn – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Confined space entry
– Building inspection
– Bar hole testing
– Purging gas purity
Measurement ranges:
– methane ppm, LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– propane ppm, LEL, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– pressure measurement 0 – 2.000 hPa (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH Allround with Ethane analysis
methane and toxic gases
Detect – Warn – Measure – Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Confined space entry
– Building inspection
– Bar hole testing
– Purging gas purity
– Ethane analysis
Measurement ranges:
– methane ppm, LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– pressure measurement 0 – 2.000 hPa (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN without Ethane analysis
GOLIATH RN without Ethane analysis
methane/propane and toxic gases
Detect – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Building inspection
– Bar hole testing
– Purging gas purity
Measurement ranges:
– methane ppm, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– propane ppm, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN with Ethane analysis
GOLIATH RN with Ethane analysis methane and toxic gases
Detect – Measure – Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing – Above ground inspection
– Building inspection – Bar hole testing
– Purging gas purity – Ethane analysis
Measurement ranges:
– methane ppm, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RB
GOLIATH RB
methane/propane and toxic gases
Warn – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Confined space entry – Bar hole testing
– Purging gas purity
Measurement ranges:
– methane LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 20 Vol.% CO2
– propane LEL, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH LOK
GOLIATH Localisation LOC
methane/propane and toxic gases
Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Purging gas purity – Bar hole testing
Measurement ranges:
– methane Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 20 Vol.% CO2
– propane Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
Dimensions: 200 x 100 x 87 mm
weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
HUNTER gas leak detector
HUNTER – gas leak detector
High sensitive professional gas detection instrument
for pipeline inspection and leak detection.
Selected sensors with humidity compensation and high sensitivity for methane.
Integrated powerful pump, rechargeable NiMH battery pack and
Bluetooth module for online data transfer to tablet computer.
Operating time:
> 10 hours including Bluetooth-data transfer
> 11 hours without Bluetooth-data transfer
Measurement range: 0 – 22.000 ppm methane
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1100 g
Temperature range: -10°C to +50°C
Laser HUNTER Gas detection & Gas measurement device
Highly sensitive and selective gas detection & gas measurement device with
laser technology for the inspection of underground gas pipes using suitable
probes (e. g. carpet probe). The device can also be used for the vehicle-based
pipeline inspection.
With built-in diaphragm pump, Bluetooth module and rechargeable
Li-Ion battery.
One out of two different laser modules can be assembled:
– single laser module for methane or
– dual laser module for methane & ethane
Moreover, the device can be equipped with additional sensors
to enable further applications.
The following applications are possible:
– Inspection of underground pipes
– Inspection of accessible pipes in buildings
– Inspection of accessible pipes on plants, etc.
– Inspection of ground soil for pinpointing (optional)
– Purging of gas pipelines (optional, only in combination with pinpointing)
– Gas analysis (with dual laser module)
Operating time up to 10 hours
Measurement range depending on built-in sensors
Dimensions (LxWxH): 143 x 240 x 85 mm
Weight: 2.1 kg
Temperature ranges:
0 °C to 40 °C (dual laser module)
-10 °C to 50 °C (single laser module)
E-Scooter Laser HUNTER
E-Scooter Ninebot MAX G30D II with mounted carpet probe for professional gas leak detection
Filter and hose for connection to measuring device Laser HUNTER are included.
The use of the scooter in German road traffic is subject to compulsory insurance!
The corresponding registration of the scooter is not part of the scope of delivery,
but is the responsibility of the customer (and the rules and regulations of the country you
reside in).
The Laser HUNTER is not part of the scope of delivery either and must be ordered separately.
HUNTER Gas detection & gas measurement device
Gas detection & gas measurement device for the inspection
of underground gas pipes using suitable probes (e. g. carpet probe).
With built-in diaphragm pump, Bluetooth module and rechargeable
Li-Ion battery.
The device can be equipped with additional sensors to enable
further applications.
The following applications are possible:
– Inspection of underground pipes
– Inspection of accessible pipes in buildings
– Inspection of accessible pipes on plants, etc.
– Inspection of ground soil for pinpointing (optional)
– Purging of gas pipes (optional, only in combination with pinpointing)
Operating approx. 10 hours
Measurement ranges depending on built-in sensors
Dimensions (LxWxH): 100 x 195 x 86 mm
Weight: 1.1 kg
Temperature range: -10°C to 50°C