Products
Device technology VibraGas / VibraGas EX portable gas detector
VibraGas / VibraGas EX portable gas detector - 271220
VibraGAS EX battery-powered gas detector
Robust, precise gas detector in an aluminium housing with a separate sensor on a gooseneck. Detects traces of gas and alerts you with audible, visual and vibrating alarms (which can be switched off).
Measuring range: 0 to 10,000 ppm methane
Operating time: > 20 hours in gas detection mode (without backlight and at 20°C)
Dimensions: 322 x 58 x 34 mm (including gooseneck)
Weight: approx. 450 g
Explosion-proof measuring device:
- marking: II 2G Ex ib d IIB T3 Gb
BVS 05 ATEX E 010 X
- temperature range: -20°C <= TA <= +50°C
VibraGas / VibraGas EX - a portable device designed for leak detection and repair (LDAR)
The flexible goose neck with remote sensor, offers the possibility for an exact examination of pipe sections, fittings and valves. Even the smallest concentrations of escaping gas are detected and displayed.
The use of VibraGAS offers numerous advantages over the use of leak spray. Hemp-sealed connections swell when using leak sprays often they are briefly "tight" again. On hard to reachline parts small bubbles can be very difficult to detect. Here, the use of a mirror for detecting the rear bubbles is often necessary. The VibraGAS works "dirt-free" and leaves no traces of wallpaper, walls or floor materials, such as leakspray.
Features of the VibraGas / VibraGas EX portable gas detector
- Robust hand-held measuring device in an ergonomic aluminum housing
- Powerful gas detector with vibration alarm and digital display reading for gas leak detection
- High contrast LCD display with backlight for an optimal display of all measurements
- Easy replacement of batteries with innovative battery Management
- Simple and easy to use thanks to intuitive menu navigation
- No need to watch the display during localisation
- Zero point can be set at the push of a button
- Practical accessories for all applications
Technical data
| Display | LCD graphic display with 128 x 64 pixels + special characters, with backlight |
|---|---|
| Power supply | pcs 1.5V Alkaline AA Batteries or EX NiMH battery pack |
| Operating time | with alkaline manganese batteries > 100 hours at pressure measurement (without lighting) > 20 hours at Gas detection (without lighting) |
| Measuring range |
0 to 10.000 ppm Methane; resolution 1, 10, 50, 100 and 1.000 ppm 0 to 200 mbar (hPa) and 200 to 2000 mbar; resolution 0,1 mbar and 1 mbar |
| Measurement precision | ± 0,5 % of end value at 200 mbar and 20°C, ±0,5 % of end value at 2.000 mbar and 20°C |
| Operating Temperature | -20 °C to +50 °C |
| Dimensions | 149–165 x 58 x 34 mm without gooseneck (gooseneck 173 mm) |
| Weight | approx. 450 g with batteries |
| Test number | BVS 05 ATEX E 010 X |
| Identification code | II 2G Ex ib d IIB T 3 Gb |