Charging technology Charging station Charging station GOLIATH / HUNTER
Charging station GOLIATH / HUNTER – 202080
Charging station GOLIATH / HUNTER
Charging station GOLIATH / HUNTER with communication interface
and mounting kit for fixing the device securely in the charging station.
USB cable included. Power supply or car adapter cable 12 V required.
Prices for customers after registration
1
Article affiliation:
HUNTER H2
Gas detection device for easily locating even the
smallest leaks in water and heating systems
– special, highly sensitive hydrogen sensor with a resolution of 0,1 ppm H2
– extremely fast reaction to the smallest traces of hydrogen
– second sensor for pinpoint localisation in probe holes
– integrated pump with high power for flow and for negative pressure
Operation time:
> 10 hours without lighting
Measuring ranges:
0 to 1000 ppm H2
0 to 5 Vol.% H2 in N2
dimensions: 200 x 100 x 87 mm
weight: approx. 1100 g
temperature range: -10°C to +50°C
HUNTER gas leak detector
HUNTER – gas leak detector
High sensitive professional gas detection instrument
for pipeline inspection and leak detection.
Selected sensors with humidity compensation and high sensitivity for methane.
Integrated powerful pump, rechargeable NiMH battery pack and
Bluetooth module for online data transfer to tablet computer.
Operating time:
> 10 hours including Bluetooth-data transfer
> 11 hours without Bluetooth-data transfer
Measurement range: 0 – 22.000 ppm methane
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1100 g
Temperature range: -10°C to +50°C
GOLIATH Allround without Ethane analysis
methane/propane and toxic gases
Detect – Warn – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Confined space entry
– Building inspection
– Bar hole testing
– Purging gas purity
Measurement ranges:
– methane ppm, LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– propane ppm, LEL, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– pressure measurement 0 – 2.000 hPa (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH Allround with Ethane analysis
methane and toxic gases
Detect – Warn – Measure – Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Confined space entry
– Building inspection
– Bar hole testing
– Purging gas purity
– Ethane analysis
Measurement ranges:
– methane ppm, LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– pressure measurement 0 – 2.000 hPa (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN without Ethane analysis
GOLIATH RN without Ethane analysis
methane/propane and toxic gases
Detect – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing
– Above ground inspection
– Building inspection
– Bar hole testing
– Purging gas purity
Measurement ranges:
– methane ppm, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– propane ppm, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN with Ethane analysis
GOLIATH RN with Ethane analysis methane and toxic gases
Detect – Measure – Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Enclosed space testing – Above ground inspection
– Building inspection – Bar hole testing
– Purging gas purity – Ethane analysis
Measurement ranges:
– methane ppm, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 100 Vol.% CO2
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RB
GOLIATH RB
methane/propane and toxic gases
Warn – Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Confined space entry – Bar hole testing
– Purging gas purity
Measurement ranges:
– methane LEL, Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 20 Vol.% CO2
– propane LEL, Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
– carbon monoxide 0 – 500 ppm CO (optional)
– hydrogen sulphide 0 – 100 ppm H2S (optional)
– flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH LOK
GOLIATH Localisation LOC
methane/propane and toxic gases
Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
– Purging gas purity – Bar hole testing
Measurement ranges:
– methane Vol.%
– carbon dioxide 0 – 5 Vol.% / 0 – 20 Vol.% CO2
– propane Vol.% (optional)
– oxygen 0 – 25 Vol.% O2 (optional)
Dimensions: 200 x 100 x 87 mm
weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C