Products
Test accessories Test gas Test gas propane 0.85 vol% - Solo 12
Article affiliation:
OLLI
Gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device.
It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with 3 alkaline manganese primary cells.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional secondary
cell and/or optional pump.
Operating time > 50 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument, marking:
II 2G Ex ib db IIB T4 Gb
BVS 17 ATEX E 043 X
Temperature range: -20°C <= Ta <= +50°C
OLLI INMETRO
OLLI INMETRO gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device. It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with a Li-Ion rechargeable battery.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional pump.
Operating time > 50 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument
Applied Brazilian standards:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60079-11
Marking: Ex db ib IIB T4 Gb
Certificates: DNV 22.0010 X
Temperature range: -20°C <= Ta <= +50°C
OLLI with certified measuring function
Gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device. It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with a Li-Ion rechargeable battery.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional pump.
Operating time > 50 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument (active & passive)
Measuring function certified for methane (CH4), propane (C3H8), oxygen (O2), carbon
monoxide (CO), carbon dioxide (CO2), hydrogen sulfide (H2S) according to the following
standards:
EN 60079-29-1
EN 50104
EN 45544-1
EN 45544-3
Marking: II 2G Ex ib db IIB T4 Gb
(EU-)type examination certificates:
BVS 17 ATEX E 043 X
TÜV 21 ATEX 8596 X
TÜV 21 PTG 7001 X
968/FSP 1940.05/21
Temperature range: -20°C <= Ta <= +50°C
OLLI INMETRO with certified measuring function
OLLI gas measurement & warning instrument
Explosion-proof & compact handheld gas measurement instrument
as diffusion device. It can be used for up to 5 combustible and toxic
gases as well as oxygen and comes in an extremely rugged
2C synthetic housing with a Li-Ion rechargeable battery.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based
on customer requirements. Moreover, a pressure sensor can be
installed. The instrument can be equipped with an optional pump.
Operating time > 50 hours (depending on type & number of installed
sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument (active & passive)
Measuring function certified for methane (CH4), propane (C3H8), oxygen (O2), carbon
monoxide (CO), carbon dioxide (CO2), hydrogen sulfide (H2S) according to the following
European standards:
EN 60079-29-1
EN 50104
EN 45544-1
EN 45544-3
Applied Brazilian standards:
ABNT NBR IEC 60079-0
ABNT NBR IEC 60079-1
ABNT NBR IEC 60079-11
Marking: Ex db ib IIB T4 Gb
Certificates: DNV 22.0010 X
Temperature range: -20°C <= Ta <= +50°C
GOLIATH Allround without Ethane analysis
methane/propane and toxic gases
Detect - Warn - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- propane ppm, LEL, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH Allround with Ethane analysis
methane and toxic gases
Detect - Warn - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
- Ethane analysis
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN without Ethane analysis
GOLIATH RN without Ethane analysis
methane/propane and toxic gases
Detect - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Building inspection
- Bar hole testing
- Purging gas purity
Measurement ranges:
- methane ppm, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- propane ppm, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN with Ethane analysis
GOLIATH RN with Ethane analysis methane and toxic gases
Detect - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing - Above ground inspection
- Building inspection - Bar hole testing
- Purging gas purity - Ethane analysis
Measurement ranges:
- methane ppm, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RB
GOLIATH RB
methane/propane and toxic gases
Warn - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Confined space entry - Bar hole testing
- Purging gas purity
Measurement ranges:
- methane LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 20 Vol.% CO2
- propane LEL, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH LOK
GOLIATH Localisation LOC
methane/propane and toxic gases
Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Purging gas purity - Bar hole testing
Measurement ranges:
- methane Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 20 Vol.% CO2
- propane Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
Dimensions: 200 x 100 x 87 mm
weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C