Products
Operating instructions Operating instructions GOLIATH
Operating instructions GOLIATH - 207011
Operating instructions GOLIATH Spanish
Environmental protection is important to us.
Therefore, we want to make a contribution in as many areas as possible.
This also includes printing our operating instructions.
We provide you with our operating instructions free of charge in our customer portal, available
at any time.
If you do need a printed version, that is of course possible.
We donate 100% of the income from the manuals to a non-profit organization
dedicated to protecting our environment.
On our website we inform you every year to which project or which organization we send our
donation to.
Article affiliation:
GOLIATH Allround without Ethane analysis
methane/propane and toxic gases
Detect - Warn - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- propane ppm, LEL, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH Allround with Ethane analysis
methane and toxic gases
Detect - Warn - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
- Ethane analysis
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN without Ethane analysis
GOLIATH RN without Ethane analysis
methane/propane and toxic gases
Detect - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Building inspection
- Bar hole testing
- Purging gas purity
Measurement ranges:
- methane ppm, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- propane ppm, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN with Ethane analysis
GOLIATH RN with Ethane analysis methane and toxic gases
Detect - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing - Above ground inspection
- Building inspection - Bar hole testing
- Purging gas purity - Ethane analysis
Measurement ranges:
- methane ppm, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RB
GOLIATH RB
methane/propane and toxic gases
Warn - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Confined space entry - Bar hole testing
- Purging gas purity
Measurement ranges:
- methane LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 20 Vol.% CO2
- propane LEL, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH LOK
GOLIATH Localisation LOC
methane/propane and toxic gases
Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Purging gas purity - Bar hole testing
Measurement ranges:
- methane Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 20 Vol.% CO2
- propane Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
Dimensions: 200 x 100 x 87 mm
weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C