Products
Transport & Storage Cases & inserts Aluminum carrying case for GOLIATH / HUNTER
Article affiliation:
HUNTER H2
Gas detection device for easily locating even the
smallest leaks in water and heating systems
- special, highly sensitive hydrogen sensor with a resolution of 0,1 ppm H2
- extremely fast reaction to the smallest traces of hydrogen
- second sensor for pinpoint localisation in probe holes
- integrated pump with high power for flow and for negative pressure
Operation time:
> 10 hours without lighting
Measuring ranges:
0 to 1000 ppm H2
0 to 5 Vol.% H2 in N2
dimensions: 200 x 100 x 87 mm
weight: approx. 1100 g
temperature range: -10°C to +50°C
GOLIATH Allround without Ethane analysis
methane/propane and toxic gases
Detect - Warn - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- propane ppm, LEL, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH Allround with Ethane analysis
methane and toxic gases
Detect - Warn - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
- Ethane analysis
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN without Ethane analysis
GOLIATH RN without Ethane analysis
methane/propane and toxic gases
Detect - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Building inspection
- Bar hole testing
- Purging gas purity
Measurement ranges:
- methane ppm, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- propane ppm, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RN with Ethane analysis
GOLIATH RN with Ethane analysis methane and toxic gases
Detect - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing - Above ground inspection
- Building inspection - Bar hole testing
- Purging gas purity - Ethane analysis
Measurement ranges:
- methane ppm, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH RB
GOLIATH RB
methane/propane and toxic gases
Warn - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Confined space entry - Bar hole testing
- Purging gas purity
Measurement ranges:
- methane LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 20 Vol.% CO2
- propane LEL, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C
GOLIATH LOK
GOLIATH Localisation LOC
methane/propane and toxic gases
Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Purging gas purity - Bar hole testing
Measurement ranges:
- methane Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 20 Vol.% CO2
- propane Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
Dimensions: 200 x 100 x 87 mm
weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°C