Device options
smart memocheck_box_outline_blankYescheck_box_outline_blankNo OLLIcheck_box_outline_blankYescheck_box_outline_blankNo MPPcheck_box_outline_blankYescheck_box_outline_blankNo GasTest delta3check_box_outline_blankYescheck_box_outline_blankNo HUNTERcheck_box_outline_blankYescheck_box_outline_blankNo Druktest maxcheck_box_outline_blankYescheck_box_outline_blankNo Menu-guided pressure test procedures for carrying out pressure tests on district heating pipes
according to AGFW FW 602 (Germany):
- Differential pressure measurement method (air)
- Pressure measurement method (air)
- Simultaneous pressure measurement (air)
- Water pressure testThe option package includes the use of the additional functions “option remote control“ and
„option air volume measurement“ in the smart memo. The period of use is one year. The
annual fee is due on date of order in terms of prepaid charges. After expiration of the period of
use the option package will be inactivated. A new or subsequent order of the option package
can be placed at any time. The annual fee can be payed for multiple years in advance.
This option package can only be used in conjunction with the motor tes pumps MPP 30-30/
MPP 70-35 and the smart memo. Another requirement is the option „flow measurement“ in
the MPP 30-30/MPP 70-35.
The following services are included:
Option remote control
This option means that the smart memo and the MPP 30-30/MPP 70-35 can communicate
with each other and exchange measured values. Test sequences for water pressure tests can be
carried out partially automated. The smart memo controls the pump and starts/stops the
pressure control/maintenance at the right time.
Option air volume measurement
With the help of this option in combination with the MPP 30-30/MPP 70-35 a determination of the residual air in the tested pipe is performed.
Directly after the end of the pressure build-up phase, a rating for the absence of air in the pipe
is displayed. With the air volume measurement, the smart memo can detect critical high air
contents at an early stage and the user is spared unnecessary time and effort. For the time
being, this function is only available for the contraction method (W 400-2/W 101/EN805).
This option can currently only be configured after the LTE-GPS Option (222610) has been
selected.Menu-guided test procedures for carrying out pressure tests on wastewater pipelines and
manholes in accordance with the regulations EN 1610 (Europe), DWA-A 139 (Germany) and
DWA-M 149-6 (Germany).
This option includes the following menu items in the device:
Wastewater Procedure Air : Carry out the tests with the test medium air in accordance with the
regulations mentioned. EDS2-P 1 bar pressure sensor required.
Wastewater Procedure water: Carry out the tests with the test medium water in accordance
with the regulations mentioned. EDS2 level probe and EDS2 dosing valve required.
The menu item "Wastewater Procedure Water" will only be completed in Q2/2023 and can be
installed via an update of the device without additional booking as soon as it is available.Annual fee for sending measurements via the Esders Connect app (Android, iOS,
Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and can also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).Measurement of the speed when flushing gas pipes in combination with the Mobile Gas Flare S (402280) or the Mobile Gas Flare M (402380).
This option requires the pressure measurement option (282124) for the OLLI (280000).Menu-driven test procedures for pressure tests on water pipes according to rules and regulations of EN 805 (Europe):
- Contraction procedure
- Normal procedureIn combination with the Esders Connect app (Android, iOS, Windows), enables the live measured values of the device to be displayed on a smartphone, tablet or PC (Android, iOS, Windows).
The zero point can also be set manually and the alarm deactivated. The function only applies to the "above-ground testing" use case (HUNTER) respectively "leak detection" (HUNTER Tracer Gas).Menu-guided test sequence for carrying out pressure tests on gas pipelines in accordance with DVGW G 469 C3 procedure (Germany).
For this menu item, the pressure curve is not evaluated by the smart memo, as this test procedure is usually evaluated by an expert.
The test measurement data is available as an Excel list in Esders Connect.Annual fee for sending measurements via the Esders Connect app (Android, iOS,
Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and can also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).Menu-driven pressure test procedures for gas pipelines according to UNE 60311 (Spain):
UNE 60311: gas lines designed for MOP <= 5 barMenu-driven pressure test procedures for gas pipelines according to following standards
(Spain):
UNE 60310: gas lines designed for 5 bar < MOP <= 16 bar
UNE EN 1594: gas lines designed for MOP > 16 barIn combination with the Esders Connect app (Android, iOS, Windows), enables the live measured values of the device to be displayed on a smartphone, tablet or PC (Android, iOS, Windows).
The zero point can also be set manually and the alarm deactivated. The function only applies to the "above-ground testing" use case.Annual fee for sending measurements via the Esders Connect app (Android, iOS, Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).Annual fee for sending measurements via the Esders Connect app (Android, iOS, Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and can also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).Menu-driven pressure test procedures for water pipes according to German DVGW W 400-2
- Contraction procedure
- Accelerated normal procedure
- Normal procedure
- Influence-minimized normal procedureIntegrated pump with a flow rate of approx. 20 l/h.
The pump forwards gas via different available probes
to the sensors. A nipple incl. filter on the upper side of
the housing is used to connect probes to the instrument.
Operating time is reduced by approx. 40% compared to
diffusion version.
Instrument dimensions with integrated pump: 171 x 78 x 43 mm
Weight: approx. 380 gOption Sensor Array
Possible measurement / indication ranges (subject to configuration):
ppm 0 - 22,000 ppm methane
LEL 0 - 100% LEL methane
Vol.% 0 - 100 Vol.% methane
Resolution is subject to chosen application
and can be set within given limits.
Measurement of combustible gases &
carbon dioxide (Dual IR sensor)
Measurement ranges:
LEL 0 - 100% LEL methane
Vol.% 0 - 100 Vol.% methane
CO2 0 - 5 Vol.%
Resolution is subject to chosen application.LTE GPS module option.
LTE and GPS module for simple, direct transmission of
Measurement and GPS position data e.g. to an e-mail address. An LTE data package is included
and permits the sending of 100 measurements (report e.g. in PDF format).To check a room for gas as well as to detect leaks in exposed pipelines indoors.
Measuring ranges:
- CH4: 0-100 vol.%
- CO: 0-300 ppm (optional)
Resolutions:
- CH4: variable, depending on measuring range
- CO: 1 ppm
This option can only be ordered in combination with the sensor array option (282102) and the
pump option (282100).